Resilient Channel For Ceilings And Walls

Resilient channel is used to reduce transmission of the airborne sound through partition and ceiling assemblies. The resilient channel dampens sound waves and transmission by suspending drywall from the wall and ceiling. Single leg resilient channel offers a higher STC rating then double leg due to less contact to the sub structure.

Quantity:
  • GOFAI
  • Stainless steel

Product Description

furring channel



Use Of Furring Channel

>>Resilient channels are a popular and efficient low-cost method of reducing sound transmission in steel or wooden framed partitions. The Resilient Channel decouples the drywall from the structure, preventing sound from traveling through.
>>Important Note: This product is NOT to be used with Resilient Sound Clips, which require Hat Channels for installation. We highly recommend the use of Resilient Sound Clips and Hat Channels for proper decoupling which will eliminate any short circuiting that Resilient Channels are prone too and will give a higher degree of decoupling.

Product Features

Dimensions: 2.0" W x .5" D
Length: 8.6' (102")
Thickness: 25 Gauge (18 Mils)
Weight: .16 LB/Ft (1.28 LB/Channel)

Installation Guidelines:
Install Resilient Channels at right angles to the framing member. The slotted holes should be positioned directly over the framing member.
Use the screw holes to attach channel. If no hole is located at the framing member, attach through the mounting flange
No more than two layers of up to 5/8" drywall should be applied.
On wall framing members, resilient channels should be installed with mounting flange on the bottom. The starter row (closest to the floor) may be installed with mounting flange upward to accommodate fastening to the frame.
Spacing:
Installing on walls: Channels should be spaced 24" OC maximum
Installing on ceillings with 24" OC Framing: Channels should be spaced 16" OC maximum
Installing on ceillings with 16" OC Framing: Channels should be spaced 24" OC maximum
Locations:
Walls: Lowest row should be no more than 2" off the floor, Highest row should be no more than 6" from the ceiling.
Ceilings: First and last row should be no more than 6" OC from adjacent wall.
Fasteners: 
Use screws only, nails should not be used.
Splicing:
Splicing should be done by nesting the ends of the resilient channel directly over the framing member and screwing through the mounting flange.
Additionally, channels can be butted over the framing member leaving a minimum 1/16" gap between channels.

Avoiding Errors with Resilient Channel Installation:
It is essential that channels be installed properly for them to work as intended.
Some main points to keep in mind:
Ensure the mounting flange is applied in the downward position. By keeping the flange down the weight of the drywall will pull the resilient channel away from the stud, thus improving the sound rating.
Screwing on top of a stud can potentially 'short circuit' the channel. Also, ensure the fastener you are using is not long enough to penetrate the stud.